Post Offer Free
Henan Xuchang Sunlight Electric and Optical Cables & Wires Co., Ltd.  

Gold Index: 8051

You are here: home  > XLPE Power Cable  > 66 / 110KV XLPE Insulated Corrugated Aluminum And PE Sheathed Underground Cables

66 / 110KV XLPE Insulated Corrugated Aluminum And PE Sheathed Underground Cables 

Place of Origin: Zhejiang, China (Mainland) 
inquire
Add to My Favorites
HiSupplier Escrow
Share |

Product Detail

Model No.: YJLW02-Z 1*630


 
66 / 110KV XLPE&n

 

66 / 110KV XLPE Insulated Corrugated Aluminum And PE Sheathed Underground Cables

 

 

Quick Detail

 

Insulation Material

XLPE

Type

High Voltage

Application

Underground

Conductor Material

Copper

Jacket

PVC

Character

waterblock

 

 

Description

 

XLPE-insulated power cables for rated voltage 110kV should perform the rules of XLPE-insulated

 Power Cable for Cable for Rated Voltage 110kV and its attachments in GB/T 11017-2002, which 

is equal to The Test Methods and Requirements of Extruded Insulation Power Cables for Voltage 30kV 

up to 150kV in IEC 60840:1999.

XLPE-insulated power cables for rated voltage 220kV should perform the rules of XLPE-insulated 

Power Cable for Cable for Rated Voltage 220kV and its attachments in GB/T 18890-2002, which is 

equal to The Test Methods and Requirements of Extruded Insulation Power Cables for Voltage 150kV 

up to 500kV in IEC 62067:2001.

XLPE-insulated power cables for rated voltage 500kV should perform the rules of XLPE-insulated 

Power Cable for Cable for Rated Voltage 220kV and its attachments in GB/T 22078-2008, which is

 equal to The Test Methods and Requirements of Extruded Insulation Power Cables for Voltage 

150kV up to 500kV in IEC 62067:2006.

XLPE-insulated power cables for rated voltage 66kV should perform The Test Methods and 

Requirements of Extruded Insulation Power Cables for Voltage 30kV up to 150kV in IEC 60840:1999.

 

 

Main Performance

 

1. The rated voltage U0/U of cables:38/66kV, 48/66kV, max. voltage Um=72.5kV;

                                 64/110kV, max. voltage Um=126kV;

                                127/220kV, max voltage Um=252kV;

                                 290/500kV, max voltage Um=550kV;

2. permissible long-term working temperature of cable conductor:90;

3. When the cable confronts short circuit within 5 seconds, the highest temperature of conductor 

should not exceed 250. When there exits line joints, the temperature of tin soldering ones should 

not exceed 120, the temperature of crimping ones should not exceed 150, and the temperature

 of electric or gas welding should not exceed 250

4. When laying, the permissible bending radius should exceed 25 times of the out diameter of the cables.

   After laying, the permissible bending radius should exceed 23 times of the out diameter of the cables.

1. When laying, ambient temperature≥0(when the cable has to be laid under the ambient temperature

bigPhoto
 Ms. Wang

Tel: 86-0374-2795966
Contact to this supplier

Related Search

Find more related products in following catalogs on Hisupplier.com

Company Info

Henan Xuchang Sunlight Electric and Optical Cables & Wires Co., Ltd. [China (Mainland)]


Business Type:Manufacturer
City: Xuchang
Province/State: Henan
Country/Region: China (Mainland)

You May Like: